nerve cuff electrodes (World Precision Instruments)
Structured Review

Nerve Cuff Electrodes, supplied by World Precision Instruments, used in various techniques. Bioz Stars score: 94/100, based on 18 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/nce/Nerve+Cuff+Electrodes/pmc12163215-56-5-23
Average 94 stars, based on 18 article reviews
Images
1) Product Images from "Acute Cervical Vagus Nerve Stimulation Modulates Gastric Slow Waves in the Distal Rat Stomach"
Article Title: Acute Cervical Vagus Nerve Stimulation Modulates Gastric Slow Waves in the Distal Rat Stomach
Journal: Neurogastroenterology and Motility
doi: 10.1111/nmo.70030
Figure Legend Snippet: Gastric slow waves were recorded from rats implanted with nerve cuff electrodes on the left cervical vagus nerve. (A) The location of incisions and placement of stimulation and recording electrodes. Photographs of (a) the vagus nerve inside the nerve cuff stimulation electrode, and (b) indicative location of multi‐electrode recording arrays on the ventral gastric serosa. (B) The flexible printed circuit board multi‐electrode arrays used to measure gastric slow waves. Gold‐plated electrodes were 0.381 mm in diameter and were arranged in a 4 × 8 grid with 0.95 mm spacing. (C) The timing of sham, stimulation, and washout segments during each sequence. In each animal, six such sequences were conducted with the order of stimulation protocols varied systematically across the four cVNS segments as tabulated in Supporting Information—Appendix .
Techniques Used: Sequencing
Figure Legend Snippet: Change in slow wave propagation in the antrum during high cervical vagus nerve stimulation. (A) Position of electrode array on the antrum of the rat stomach. The green box indicates the mapped portion of the array in (F). (B) Locations of electrodes plotted in (E), shown within the green box indicating the area of mapped activation times in (F). Coordinated slow wave propagation was seen before and after stimulation. For each wave the mean ± one standard deviation across channels in the array is shown for (C) slow wave speed and (D) slow wave interval. Both quantities transition back to the pre‐stimulation state following the cessation of cervical vagus nerve stimulation. (E) Traces from a line of electrodes (1.34 mm diagonal spacing) showing the propagation of activity from proximal to distal in the pre‐stimulation, and stable post‐stimulation states. The grouped events of a single propagating wave are marked by a blue arrow to show propagation direction. (F) Maps of isochronal slow wave activation times showing waves for each state. Black arrows indicate the directions of propagation in each map, and a blue star indicates the wave annotated in (E).
Techniques Used: Activation Assay, Standard Deviation, Activity Assay
Related Articles
Generated:Article Title: Nerve block by electrical pulses at sub-threshold intensity Article Snippet: .. HFBS (6 or 10 kHz square waveform without a pulse interval, see FIG. 14) generated by a computer running a LabView program (National Instrument, TX, USA) was delivered via a stimulation isolator (A395, World Precision Instruments, FL, USA) to the tripolar Article Title: Nerve block by electrical pulses at sub-threshold intensity Article Snippet: .. HFBS (6 or 10 kHz square waveform without a pulse interval, see FIG. 14) generated by a computer running a LabView program (National Instrument, TX, USA) was delivered via a stimulation isolator (A395, World Precision Instruments, FL, USA) to the tripolar Blocking Assay:Article Title: Nerve block by electrical pulses at sub-threshold intensity Article Snippet: .. HFBS (6 or 10 kHz square waveform without a pulse interval, see FIG. 14) generated by a computer running a LabView program (National Instrument, TX, USA) was delivered via a stimulation isolator (A395, World Precision Instruments, FL, USA) to the tripolar Article Title: Nerve block by electrical pulses at sub-threshold intensity Article Snippet: .. HFBS (6 or 10 kHz square waveform without a pulse interval, see FIG. 14) generated by a computer running a LabView program (National Instrument, TX, USA) was delivered via a stimulation isolator (A395, World Precision Instruments, FL, USA) to the tripolar |